| Features: |
Input 340 ~ 550 VACm 3-phase 4 wires
UL508 listed
Hight efficiency up to 92% Optional parallel function (1+1)
Installed on DIN rail TS35/7.5 or 15
100% burn - in test
3 years warranty |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| AC Input Voltage Range |
340~550VAC; 3-Phase 4 wires |
| AC Inrush Current |
cold start, 50A |
| DC Adjustment Range |
24~28V for 24V model, 48~55V for 48V model |
| Over load Protection |
105%~150% constant currentlimiting, shut off after 3 sec. |
| Over voltage protection |
30~36V for 24V model, 59~66V for 48V shut off, AC recycle to re-start |
| Withstand Voltage¡@ |
I/P-O/P: 3KVAC, I/P-FG:1.5KVA, O/P-FG: 0.5 KVAC, 1 minute |
| Working Temperature |
-20 ~+40¢XC @ 100%, 70¢XC at 60% load |
| Safety standard |
UL508, UL60950-1, TUV EN60950-1 approved |
| EMC Standards |
EN55022 class B, EN61000-3-2,3 EN61204-3, EN61000-4-2,3,4,5,6,8,11, EN50204, EN61000-6-2 heavy industry lev |
| Connection |
I/P: 4 P, O/P: 6 P screw DIN terminal |
| Weight/packing |
3.3kgs; 4 pcs / 14.2 kgs / 1.14 CUFT |
| Dimension |
276 X 125.2 X 100 mm |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
DRT-960-24 |
340~550 VAC |
+ 24.00VDC |
.00A |
40.00A |
±% |
960.000(w) |
| 2. |
DRT-960-48 |
90~264 VAC |
+ 48.00VDC |
.00A |
20.00A |
±.00% |
960.000(w) |
| Other Informations: |
| DRT-960 |
 |
|
|