| Features: |
Universal Input
IEC320 Receptacle 2P or 3P
Optional Output Connector
OVP, OPP, Auto Recovery |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input Voltage |
100 ~240 ¡Ó10% VAC, full load |
| Input Frequency |
47~63 Hz |
| Input Current |
1.0A Max......115VAC, full load |
| |
0.5A Max ...... 230VAC, full load |
| Efficiency |
70% Min. at full load, nominal line |
| Inruch Current |
20A Max. ...... 115VAC, cold start |
| |
40A Max. ...... 230VAC, cold start |
| Hold Up Time |
20mS at full load, nominal line |
| Trun-on Time |
2.5 Sec. Max. at AC115V, cold start |
| Configuration |
3-wire input AC line |
| Hi-Pot tests |
1.8K VAC for 3 seconds |
| Leakage Current |
10mA |
| R&N |
+ 5VDC ...... 50mV |
| |
+12VDC ...... 150mV |
| Over Current Protection |
Output 1: +5V ...... 6A Max. at output 2 full load |
| |
Output 2: +12V ...... 4A Max. at output 1 full load |
| Protection |
OCP, OVP, over power, short circuit & over shoot |
| Operating Temperature |
0¢XC ~ +40¢XC |
| Storage Temperature |
-20¢XC ~ +85¢XC |
| Operating Humidity |
10% ~ 90% RH |
| Storage Humidity |
5% ~ 90% RH |
| Altitude |
Operation ...... 10,000 feet |
| |
Storage ...... 40,000 feet |
| Safety |
UL,cUL,TUV |
| EMI |
FCC class B, EN55022 |
| Dimensions |
L 115 X W 51 X H28 mm |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
F1760 |
100~240 VAC |
+ 5.00VDC + 12.00VDC |
.00A .00A |
2.00A 2.00A |
±5.00% ±5.00% |
34.000(w) |
| Other Informations: |
| F1760 |
 |
|
|