| Features: |
Double side PCB for high reliability
Built-In class B EMI filter (AC or DC input)
DC inputs 12VDC, 24VDC, 48VDC for DC/DC Low leakage current medical model (Optional)
CE marked to low voltage directive (LVD) |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input voltage |
90 ~ 264 VAC |
| Input frequency |
47 ~ 63 Hz |
| Inrush current |
35 A typical, cold start @ 25 ¢XC, 115 VAC |
| Hold-up time |
16mS typical at full load @ 115 VAC |
| Turn-on time |
1 sec. max. at full load @ 115 VAC |
| Line Regulation |
¡Ó 0.5% typical |
| Load Regulation |
Main output ¡Ó 5 %, AUX. Outputs ¡Ó 10 % Typical (Note 1) |
| Efficiency |
> 65% typical at full load |
| Noise & Ripple |
1% typical full load (Note 2) |
| Remote sense |
250 mV ¡Ó 50mV @V1 at full load |
| Operating Temperature |
0 ¢J to +50 ¢J |
| Storage Temperature |
-40 ¢J to +85 ¢J |
| Protections |
OVP, OCP, Short circuit protection |
| Safety |
UL_cus, CE-TBD., TUV TBD. |
| EMI conducted / radiated |
FCC & CISPR class B, meets EN61000-3-3, -4-2, -3, -4, -5, -6, -8, -11 |
| Dimensions |
5" x 3.3" x 1.5" |
| Notices: |
Note 1: Cross/ Load regulation is tested at 10% to 100% of reated load and other outputs are set at 50% of rate laod.
Note 2: Measurements with 20MHZ bandwidth and terminated with a 10uF electrolytic cap. in parallel with a 0.1uF ceramic cap. |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
LTE90U-D12 |
90-264 VAC |
+ 5.00VDC + 12.00VDC |
1.00A .40A |
10.00A 4.00A |
±5.00% ±5.00% |
90.000(w) |
| 2. |
LTE90U-D |
90-264 VAC |
+ 5.00VDC + 24.00VDC |
1.00A .20A |
10.00A 2.00A |
±5.00% ±5.00% |
90.000(w) |
| 3. |
LTE90U-D1B |
90-264 VAC |
+ 5.00VDC - 5.00VDC |
1.00A .00A |
10.00A 10.00A |
±5.00% ±10.00% |
90.000(w) |
| 4. |
LTE90U-D24 |
90-264 VAC |
+ 12.00VDC + 24.00VDC |
.42A .21A |
4.20A 2.10A |
±5.00% ±10.00% |
90.000(w) |
| 5. |
LTE90U-D2C |
90-264 VAC |
+ 12.00VDC - 12.00VDC |
.42A .42A |
4.20A 4.20A |
±5.00% ±10.00% |
90.000(w) |
| 6. |
LTE90U-Q02C1 |
90-264 VAC |
+ 3.30VDC + 12.00VDC - 12.00VDC + 5.00VDC |
1.00A .30A .10A .10A |
10.00A 3.00A 1.00A 1.00A |
±5.00% ±5.00% ±10.00% ±10.00% |
90.000(w) |
| 7. |
LTE90U-Q12C4 |
90-264 VAC |
+ 5.00VDC + 12.00VDC - 12.00VDC + 24.00VDC |
.80A .30A .10A .05A |
8.00A 3.00A 1.00A .50A |
±5.00% ±5.00% ±10.00% ±10.00% |
90.000(w) |
| 8. |
LTE90U-Q12C5 |
90-264 VAC |
+ 5.00VDC + 12.00VDC - 12.00VDC + 48.00VDC |
.80A .30A .10A .02A |
8.00A 3.00A 1.00A .25A |
±5.00% ±5.00% ±10.00% ±10.00% |
90.000(w) |
| 9. |
LTE9U-Q12CB |
90-264 VAC |
+ 5.00VDC + 12.00VDC - 12.00VDC - 5.00VDC |
.80A .30A .15A .10A |
8.00A 3.00A 1.50A 1.00A |
±5.00% ±5.00% ±10.00% ±10.00% |
90.000(w) |
| 10. |
LTE90U-Q13D4 |
90-264 VAC |
+ 5.00VDC + 15.00VDC - 15.00VDC + 24.00VDC |
.80A .24A .12A .05A |
8.00A 2.40A 1.20A .50A |
±5.00% ±5.00% ±10.00% ±10.00% |
90.000(w) |
| 11. |
LTE90U-S0 |
90-264 VAC |
+ 3.30VDC |
.00A |
18.00A |
±3.00% |
90.000(w) |
| 12. |
LTE90U-S1 |
90-264 VAC |
+ 5.00VDC |
.00A |
18.00A |
±3.00% |
90.000(w) |
| 13. |
LTE90U-S2 |
90-264 VAC |
+ 12.00VDC |
.00A |
7.50A |
±3.00% |
90.000(w) |
| 14. |
LTE90U-S3 |
90-264 VAC |
+ 15.00VDC |
.00A |
6.00A |
±3.00% |
90.000(w) |
| 15. |
LTE90U-S4 |
90-264 VAC |
+ 24.00VDC |
.00A |
3.75A |
±3.00% |
90.000(w) |
| 16. |
LTE90U-S5 |
90-264 VAC |
+ 48.00VDC |
.00A |
1.87A |
±3.00% |
90.000(w) |
| 17. |
LTE90U-T012 |
90-264 VAC |
+ 3.30VDC + 5.00VDC + 12.00VDC |
1.20A .80A .15A |
12.00A 8.00A 1.60A |
±5.00% ±5.00% ±10.00% |
90.000(w) |
| 18. |
LTE90U-T124 |
90-264 VAC |
+ 5.00VDC + 12.00VDC + 24.00VDC |
.90A .35A .05A |
9.00A 3.50A .50A |
±5.00% ±5.00% ±10.00% |
90.000(w) |
| 19. |
LTE90U-T12B |
90-264 VAC |
+ 5.00VDC + 12.00VDC - 5.00VDC |
1.00A .35A .15A |
10.00A 3.50A 1.50A |
±5.00% ±5.00% ±10.00% |
90.000(w) |
| 20. |
LTE90U-T12C |
90-264 VAC |
+ 5.00VDC + 12.00VDC - 12.00VDC |
.90A .35A .10A |
9.00A 3.50A 1.00A |
±5.00% ±5.00% ±10.00% |
90.000(w) |
| 21. |
LTE90U-T14C |
90-264 VAC |
+ 5.00VDC + 24.00VDC - 12.00VDC |
.90A .18A .10A |
9.00A 1.80A 1.00A |
±5.00% ±5.00% ±10.00% |
90.000(w) |
| Other Informations: |
| LTE90U |
 |
|
|