| Specifications: |
| Parameter | Description/SPEC.: |
| Input voltage | 85 ~ 264 VAC or 120 ~ 370 VDC |
| Power Factor | PF> 0.95 / 230 VAC, PF > 0.98 / 115VAC at full load |
| AC Inrush current (max.) | Cold start, 40 A at 230 VAC for MP-450 Model |
| | Cold start, 50 A at 230 VAC for MP-650 Model |
| | Cold start, 50 A at 230 VAC for MP-1000 Model |
| Max. output wattage | 450 W for MP-450 / 650 W for MP-650 / 1000 W for MP-1000 |
| Efficiency (typical) | 83% for MP-450 / 85% for MP-650 / 85% for MP-1000 |
| Protections | Short circuit, over load, over voltage protections for all modules |
| Over temperature protection | Output shutdown, auto-recovery |
| Fan Alarm | Output shutdown when fan malfunction |
| Withstand voltage | I/P-O/P: 3K VAC, I/P-FG: 1.5KVAC, 1min. |
| Working temperature | -20¢J ~ +50¢J at 100%, +70¢J at 50% load (refer to output derating curve) |
| Safety standard | UL60950-1, TUV EN60950-1 |
| EMC stnadard | EN55022 class B, EN55024, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN55024 light industry level, criteria A |
| Connection | Input side: 3P/10mm pitch terminal block & JST B3B-XH |
| Dimension (L X W X H) | 254 X 127 X 63.5 mm for MP-450 / 278 X 127 X 63.5 mm for MP-650 / 278 X 177.8 X 63.5 mm for MP-1000 |