Untitled Document
| Features: |
Universal AC input/ Full range
PFC0.98@115VAC, 0.94@230VAC
Free air cooling convection
Short circuit protection/ OLP/ OVP
Approvals:UL/CUL/TUV/CB/CE
3 years warranty |
|
| Specifications:¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@¡@ |
| Parameter |
Description/SPEC.: |
| Input Voltage |
90 ~ 264 VAC, 127 ~ 370 VDC |
| Inrush Current |
cold start, 45A / 230V ( typical ) |
| DC adjust range |
CH1: -5% ~ +10% rated output vol. |
| O.L.P. |
CH1: 105% ~ 150% hiccup mode, auto recovery |
| O.V.P. |
115% ~ 135% for CH1 or CH1 & 2 |
| Withstand voltage: |
I/P-O/P: 3K VAC, I/P-FG: 1.5K VAC, 1minute |
| Working temp |
-10¢XC ~ 60¢XC ( Refer to output de-rating curve ) |
| Safety standard |
UL60950-1, TUV EN60950-1 |
| EMC Standard |
EN55022 class B, ENV50204, EN61000-4-2,3,4,5,6,8,11,
EN61000-3-2,3 |
| Connection |
7.62 mm pitch terminal block with cover |
| Packing |
0.93 kg; 20 pcs / 19.6 kgs / 1.28 CUFT |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
QP-150-3A |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 3.30VDC
+ 12.00VDC
- 5.00VDC |
3.00A
.10A
.40A
.00A |
15.00A
15.00A
5.00A
1.00A |
±3.00%
±3.00%
±6.00%
±5.00% |
146.000(w) |
| 2. |
QP-150-3B |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 3.30VDC
+ 12.00VDC
- 12.00VDC |
3.00A
.00A
.40A
.00A |
15.00A
15.00A
5.00A
1.00A |
±3.00%
±3.00%
±6.00%
±5.00% |
150.000(w) |
| 3. |
QP-150-3C |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 5.00VDC
+ 3.30VDC
+ 3.30VDC
- 12.00VDC
+ 15.00VDC
+ 12.00VDC
- 15.00VDC |
3.00A
3.00A
.00A
.00A
.00A
.40A
.40A
.00A |
15.00A
15.00A
15.00A
15.00A
1.00A
5.00A
5.00A
1.00A |
±3.00%
±3.00%
±3.00%
±3.00%
±5.00%
±7.00%
±6.00%
±5.00% |
152.000(w) |
| 4. |
QP-150-3D |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 3.30VDC
+ 24.00VDC
- 12.00VDC |
3.00A
.00A
.30A
.00A |
15.00A
15.00A
3.00A
1.00A |
±3.00%
±3.00%
±6.00%
±5.00% |
150.000(w) |
| 5. |
QP-150B |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 12.00VDC
- 5.00VDC
- 12.00VDC |
3.00A
.40A
.00A
.30A |
15.00A
5.00A
1.00A
2.00A |
±3.00%
±6.00%
±5.00%
±8.00% |
150.000(w) |
| 6. |
QP-150C |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 15.00VDC
- 5.00VDC
- 15.00VDC |
3.00A
.40A
.00A
.30A |
15.00A
4.00A
1.00A
2.00A |
±3.00%
±8.00%
±5.00%
±8.00% |
153.000(w) |
| 7. |
QP-150D |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 12.00VDC
+ 24.00VDC
- 12.00VDC |
3.00A
.00A
.40A
.00A |
15.00A
5.00A
3.00A
1.00A |
±3.00%
±3.00%
±6.00%
±5.00% |
150.000(w) |
| 8. |
QP-150F |
90~264VAC, 127~370 VDC |
+ 5.00VDC
+ 15.00VDC
+ 24.00VDC
- 15.00VDC |
3.00A
.00A
.40A
.00A |
15.00A
5.00A
3.00A
1.00A |
±3.00%
±3.00%
±6.00%
±5.00% |
152.000(w) |
| Other Informations: |