| Features: |
Universal AC inlet / full range
Using ZVStechnology to reduce power dissipation
High power density 5.48 W/in³ PF>0.98 @ 115 VAC; >0.95 @ 230 VAC
Built-in remote sense and on/off control
With PG/PG signal output
3 years warranty |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| AC Input voltage |
90 ~ 264 VAC; 127 ~ 370 VDC |
| AC inrush current |
Cold start, 50A at 230 VAC |
| DC adjustment range |
¡Ó 10% rated output boltage |
| Setup, rise, hold up time |
600 ms, 50 ms, 16 ms at full load and 230VAC |
| O.L.P. |
105%~125% constant current limiting, hiccup after 3 sec. |
| O.V.P |
115%~140% of output voltge |
| Withstand voltage |
I/P-O/P: 3KV, I/P-FG: 1.5KV, 1 minute |
| Working temperature |
-20 ~ 50¢J @100%, 60¢J @ 60% load |
| Protections |
Short circuit / OVP/ OLP |
| Safety standard |
UL60950-1,TUV EN60950-1 approbed |
| EMC standard |
EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, ENV50204, en61000-6-2 |
| Connection |
5P/10mm pitch terminal block with cover for input, copper pillars for output |
| Weight/packing: |
2.9 kgs ; 6 pcs / 18.4 kgs / 0.98 CUFT |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
SP-750-12 |
90~264 VAC |
+ 12.00VDC |
.00A |
62.50A |
±.00% |
750.000(w) |
| 2. |
SP-750-15 |
90~264 VAC |
+ 15.00VDC |
.00A |
50.00A |
±.00% |
750.000(w) |
| 3. |
SP-750-24 |
90~264 VAC |
+ 24.00VDC |
.00A |
31.30A |
±.00% |
750.000(w) |
| 4. |
SP-750-27 |
90~264 VAC |
+ 27.00VDC |
.00A |
27.80A |
±.00% |
750.000(w) |
| 5. |
SP-750-48 |
90~264 VAC |
+ 48.00VDC |
.00A |
15.70A |
±.00% |
750.000(w) |
| 6. |
SP-750-5 |
90~264 VAC |
+ 5.00VDC |
.00A |
120.00A |
±.00% |
750.000(w) |
| Other Informations: |