| Features: |
Universal AC input / full range
Fix switching frequency at 40 KHz
Approvals: CSA / CE/ NRTLC 100% full load burn-in test
Protections: Short circuit / OLP / OVP
2 years warranty |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input Voltage |
85 ~ 264 VAC ; 120 ~ 370 VDC |
| Input Frequency |
47 ~ 63 Hz |
| Inrush Current |
cold start, 20A / 115 V, 40A / 230V |
| O.L.P. |
105% ~ 150% / 115 VAC output pulsing mode |
| O.V.P. |
CH1:115%~135% of output voltage |
| Setup,Rise,Hold Up Time |
800ms, 50ms, 60ms / 230 VAC |
| Withstand voltage |
I/P-O/P:3KV, I/P-FG:1.5KV, 1min. |
| Working temp. |
0 ¢J ~ 50 ¢J @ 100%, -10 ¢J @ 80%, 60 ¢J @ 60% load |
| Safety standard |
CSA 60950-1 approved |
| EMC Standard |
EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3 ENV50204 |
| Connection |
7 P / 9.5 mm pitch terminal block with cover |
| Weight / packing |
0.44 kg / pc; 30 pcs / 14.7 kgs / 0.86 CUFT |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
T-40A |
85~264VAC; 120~370 VDC |
+ 5.00VDC + 12.00VDC - 5.00VDC |
.60A .20A .10A |
5.00A 3.00A 1.00A |
±2.00% ±6.00% ±8.00% |
40.000(w) |
| 2. |
T-40B |
85~264VAC; 120~370 VDC |
+ 5.00VDC + 12.00VDC - 12.00VDC |
.60A .20A .10A |
5.00A 3.00A 1.00A |
±2.00% ±6.00% ±8.00% |
40.000(w) |
| 3. |
T-40C |
85~264VAC; 120~370 VDC |
+ 5.00VDC + 15.00VDC - 15.00VDC |
.60A .20A .10A |
5.00A 2.00A 1.00A |
±2.00% ±6.00% ±6.00% |
40.000(w) |
| Other Informations: |
| Mechanical Drawimg : ( mm ) |
 |
|
|