| Features: |
Universal AC input / Full range
PFC > 0.98 @ 115VAC, > 0.95 @ 230VAC
Thin profile (33mm thick)
Free air cooling convection Protections: Short circuit / OLP / OVP
Fix switching frequency at 134 KHz
Approvals:UL/cUL/TUV/CB/CE
3 years warranty |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input Voltage |
90 ~ 264 VAC, 120 ~ 370 VDC |
| Inrush Current |
cold start, 40 A at 230 VAC |
| DC adjust range |
CH1: -5 ~ +10% rated output vol. |
| O.L.P. |
105% ~ 150% hiccup mode, auto recovery |
| O.V.P. |
CH1: 115% ~ 135% rated output vol. |
| Withstand voltage |
I/P-O/P: 3K VAC, I/P-FG: 1.5K VAC, 1minute |
| Working temp |
-10 ¢J ~ 60 ¢J (refer to output derating curve) |
| Safety standard |
UL60950-1, EN60950-1 |
| EMC Standard |
EN50204, N55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 |
| Connection |
8 P / 7.62 mm pitch terminal block |
| Weight / packing |
0.65 kg/pc; 20 pcs / 12.7 kgs / 0.64 CUFT |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
TP-7503 |
90~264VAC; 120~370 VDC |
+ 5.00VDC + 3.30VDC + 24.00VDC |
1.50A .20A .00A |
10.00A 8.00A .60A |
±3.00% ±4.00% ±8.00% |
75.000(w) |
| 2. |
TP-75A |
90~264VAC; 120~370 VDC |
+ 5.00VDC + 12.00VDC - 5.00VDC |
.50A .20A .00A |
10.00A 4.00A .60A |
±3.00% ±4.00% ±8.00% |
75.000(w) |
| 3. |
TP-75B |
90~264VAC; 120~370 VDC |
+ 5.00VDC + 12.00VDC - 12.00VDC |
.50A .20A .00A |
10.00A 4.00A .60A |
±3.00% ±4.00% ±8.00% |
75.000(w) |
| 4. |
TP-75C |
90~264VAC; 120~370 VDC |
+ 5.00VDC + 15.00VDC - 15.00VDC |
1.50A .20A .00A |
10.00A 3.00A .60A |
±3.00% ±4.00% ±8.00% |
75.000(w) |
| 5. |
TP-75D |
90~264VAC; 120~370 VDC |
+ 5.00VDC + 24.00VDC + 12.00VDC |
1.50A .20A .00A |
10.00A 1.50A .60A |
±3.00% ±4.00% ±8.00% |
75.000(w) |
| Other Informations: |
| Mechanical Drawimg : ( mm ) |
 |
|
|