| Features: |
Ac Input Range Selected By Switch
Protection : OLP , OVP , OTP , Short CKT
3 color LED loading indicator Battery Unde / Over Voltage Polarity Protection (ESC only)
Fix Switching Frequency At 25 KHz |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input voltage |
88 ~ 132 / 176 ~ 264 VAC selected by SW. |
| Inrush current |
cold start, 35 A at 230 VAC |
| Dc adjust range |
13.5 V ( 12 ~ 15 V ) , 27 V ( 24 ~ 30 V ), 54 V ( 48 ~ 56 V ). |
| O.L.P. |
105% ~ 135% fold back current limiting, Auto recovery |
| O.V.P. |
115% ~ 135% rated output Voltage |
| Setup, rise, hold up time |
200 ms , 100 ms, 15 ms at full load and 230 VAC |
| Withstand voltage |
I/P-O/P: 3 KV, I/P-FG: 1.5 KV, 1min. |
| Working temp. |
0 ~ 35¢XC @ 100%, -10¢XC @ 80%, 60¢XC @ 60% |
| Safety standard |
CSA1010.1 (UL3101-1, IEC1010-1, EN60101-1), CSA60950-1 |
| EMC standard |
EN55022 class B, EN61000-4-2,3,4, EN61000-3-2, 3, ENV50204 |
| Weight / packing |
1.38 kgs / pc; 8 pcs / 12 kgs / 1.1 CUFT |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
ESC-120-13.5 |
88~132/176~264 VAC |
+ 13.50VDC |
.00A |
8.00A |
±2.00% |
108.000(w) |
| 2. |
ESC-120-27 |
88~132/176~264 VAC |
+ 27.00VDC |
.00A |
4.00A |
±1.00% |
108.000(w) |
| 3. |
ESC-120-54 |
88~132/176~264 VAC |
+ 54.00VDC |
.00A |
2.00A |
±1.00% |
108.000(w) |
| 4. |
ESP-120-13.5 |
88~132/176~264 VAC |
+ 13.50VDC |
.00A |
8.00A |
±2.00% |
108.000(w) |
| 5. |
ESP-120-27 |
88~132/176~264 VAC |
+ 27.00VDC |
.00A |
4.00A |
±1.00% |
108.000(w) |
| 6. |
ESP-120-54 |
88~132/176~264 VAC |
+ 54.00VDC |
.00A |
2.00A |
±1.00% |
108.000(w) |
| Other Informations: |
| ESC/ESP-120 |
 |
|
|